<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-19 14-09-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 33 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
7 kHz 10 kHz 15141 0,0264
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -1,05 dBr 0,3 dBr 1,6
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 14:09, 19.04.2024
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 10 kHz MIN: 7 kHz % above 77 kHz: 0,0264 Acquired: 2024/04/19 14:09:17 Total samples: 15141 Equivalent time: 0:12:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600